- Reduced ambient dripping particles of fluid pipes
- Fixed reversed uvs on encased fans
- Fixed tile entities not being added to contraptions client-side
- Added encased and non-opaque versions of the fluid pipe.
- Added new generic te behaviour across pipe blocks for their rims/attachment models
- Pipes and pumps now render a little drain cap when connected to a fluid inventory
- Implemented reworked chute models by Kryppers
- Implemented new basin model by Kryppers
- Chutes now have proper selection bounds
- Some minor texture & model touch-ups
- Fixed symmetry wand position in its GUI
- Fixed some inconsistencies with a tanks' fluidhandler invalidation when resized
- Patched crashes in present fluid handling of the basin
- Tanks now slightly shade horizontal faces of the contained liquid
- Tanks no longer resend data every tick when filled gradually
- Introduced a new lerped value type with better design decisions
- Refactored Smart tileentity serialization to better support custom overrides in contained behaviours
- Pumps propagate flows in the pipe networks in front and behind itself.
- Pumps collect all possible in and outputs across the reachable pipe graph as endpoints
- Flows move across multiple branches of a pipe network when both are equally viable
- Open-ended pipes are treated as endpoints and leak fluid into and out of a block space
- Open endpoints serialize stateful information about fluid units gathered and held at the interface
- Open endpoints turn a fluid block into 1000 fluid units and back
- Open endpoints undo their transaction when their flow changes from pull to push
- Open endpoints cannot pull fluids back when a full liquid block was not placed yet
- Open endpoints waterlog blocks when the provided fluid is water
- A collision response is triggered when different types of fluids meet at open endpoints
- Fluids are transferred instantly by the throughput of a completed flow per tick
- Pumps cut flows when vital pipes are removed
- Pumps do not lose progress of finished flows when an unrelated part of the pipe network changes
- Pumps do not lose progress of finished flows when reversed
- Pumps distribute their throughput across available input flows evenly
- Pumps distribute gathered input fluid across outputs evenly
- Pumps expose furthest reachable pipefaces to other pumps for chained transfer
- Chained pumps with fully overlapping flow sections provide their endpoints at the entrance of the other pump
- Chained pumps with overlapping flow sections participate in two shared endpoints, one for each pump dominating the contested region
- Chained pumps with overlapping flow only transfer via the optimal of the two possible endpoints based on their speeds
- Chained pumps of equal speed pick one of the two available endpoints deterministically
- Pumps transfer without flows when no pipe is between the pump and the endpoint
- Pumps serialize and recover stateful information about held fluid units at open endpoints
- Chained pumps do not actively transfer when both are partaking with push flows (or both pulling)
- A pull flow originating from an inter-pump endpoint only commences when the corresponding push flow is completed
- Chained pumps re-determine the optimal flow when the speed of one is changed at runtime
- Throughput of chained pumps is determined by their weakest link in terms of speed
- Endpoints created for chained pumps is treated equally to other available endpoints when fluid is distributed
- Pipes do not contain a physical amount of fluid.
- Pipes never hold serialized vital stateful information about fluid transfer.
- Pipes synchronize local flow progress and fluid type to clients
- Flows in a pipe progress with the speed of the network flow
- A networks flow speed depends on the speed of the aggregated pump
- Pipe flows of different flow graphs of different pumps interact with each other
- A collision response is triggered when two different types of fluid meet within a pipe
- Pipes spawn particles to illustrate contained flows/liquids of flows
- The fluid transfer role is exposed through a TE behaviour with some callbacks and properties
- Open endpoints show particles when interacting with in-world fluids
- buffering SeatMovementBehaviour
- changed visibility of AllMovementBehaviours.addMovementBehaviour(ResourceLocation, MovementBehaviour) to public for easier mod compat
- added console warn message when something tries to register more than one movement behaviour per block
- Seats now pick up non-player entities when touching them while being moved
- Seats now drop off entities when being moved into a solid block
- Previously colliding entities now get moved to match their position on the placed structure on disassembly
- Contraption motion no longer gets fed into the collision response for non-minecart contraptions
- The server now gets frequent updates about client players riding a contraption, fixes instabilities with projectiles, damage and anti-fly detection
- Players can now take fall damage when colliding with contraptions