In the conversion to `parse_boolean` for `cmd_ws_auto_back_and_forth`,
the `negation` was never removed causing the setting to be the opposite
of what it should be.
`i3 4.16` allows users to list multiple outputs for a workspace and the
first available will be used. The syntax is as follows:
`workspace <workspace> output <outputs...>`
Additionally when the workspace is created, the outputs get added to the
output priority list in the order specified. This ensures that if a higher
output gets connected, the workspace will move to the higher output. This
works the same way as if the user had a workspace on an output, disconnected
the output, and then later reconnected the output.
This implements the following syntaxes from `i3 4.16`:
* `resize set [width] <width> [px|ppt]`
* `resize set height <height> [px|ppt]`
* `resize set [width] <width> [px|ppt] [height] <height> [px|ppt]`
Additionally, a bug was fixed that caused setting the height of a tiled
container to change the width instead due to a typo.
This introduces the following command extensions from `i3-gaps`:
* `gaps horizontal|vertical|top|right|bottom|left <amount>`
* `gaps horizontal|vertical|top|right|bottom|left all|current
set|plus|minus <amount>`
* `workspace <ws> gaps horizontal|vertical|top|right|bottom|left
<amount>`
`inner` and `outer` are also still available as options for all three
of the above commands. `outer` now acts as a shorthand to set/alter
all sides.
Additionally, this fixes two bugs with the prevention of invalid gap
configurations for workspace configs:
1. If outer gaps were not set and inner gaps were, the outer gaps
would be snapped to the negation of the inner gaps due to `INT_MIN`
being less than the negation. This took precedence over the default
outer gaps.
2. Similarly, if inner gaps were not set and outer gaps were, inner
gaps would be set to zero, which would take precedence over the
default inner gaps.
Fixing both of the above items also requires checking the gaps again
when creating a workspace since the default outer gaps can be smaller
than the negation of the workspace specific inner gaps.
This commit enhances the output transform
command with options for a relative transform,
i.e. the provided transform will be applied as
an offset to the current transform. Append
`clockwise` to rotate clockwise from the current
rotation, or `anticlockwise` to rotate in the
opposite direction.
For example, if the output LVDS-1 is rotated
90 degrees clockwise, the command
`output LVDS-1 transform 90 clockwise`
will rotate the display to 180 degrees.
All transform options are supported,
including flipped transforms.
Relative transforms can only be applied to
a single output and cannot be used with
a wildcard (*) output specifier.
The exec_always command was executed twice, since it was not checking for the
config->validating variable.
Fix this by defering the command if the configuration is validating.
Fixes#3072
It appears that the focus code that handles `focus_wrapping yes` was
removed during the conversion to type safety. This re-implements the
focus code for when `focus_wrapping` is set to `yes` (default). Neither
the `no` or `force` options appear to be effected and should be working.